On the nature of indoor airborne bioaerosols at a hospital in Iran
Author/Authors :
Dashti, Maryam Department of Environmental Health Engineering - School of Public Health - Ardabil University of Medical Science - University of Medical Science Ardabil , Norouzian Baghani, Abbas Department of Environmental Health Engineering - School of Public Health - Tehran University of Medical Sciences, Tehran , Sorooshian, Armin Department of Chemical and Environmental Engineering - University of Arizona, Tucson, Arizona, USA , Vosoughi, Mehdi Department of Environmental Health Engineering - School of Public Health - Ardabil University of Medical Science - University of Medical Science Ardabil , Mokhtari, Ahmad Department of Environmental Health Engineering - School of Public Health - Ardabil University of Medical Science - University of Medical Science Ardabil , Sadeghi, Hadi Department of Environmental Health Engineering - School of Public Health - Ardabil University of Medical Science - University of Medical Science Ardabil
Pages :
16
From page :
14
To page :
29
Abstract :
Introduction: Hospitals are sensitive places owing to the contagious nature of diseases transferred by patients to others such as health care workers and staff. Materials and methods: The aim of the present work is to evaluate the type and concentration of bacterial and fungal bio-aerosols in the indoor air of four operating rooms (ORs) and four wards in Khalkhal, Iran during 2019. A total of 192 bacterial and fungal samples were collected. Results: Mean total concentrations of airborne bacteria for ORs and wards were between 11±1.2 to 48±3.1 CFU/m3, respectively, while for airborne fungi values ranged from 95±5.6 to 51±1.2 CFU/m3, respectively. The predominant genera of airborne bacterial isolated (ORs vs. wards) were Staphylococcus epidermidis (72% vs. 58%), Group D Streptococcus (4% vs. 17%), Group A Streptococcus (13% vs. 3%), and Staphylococcus saprophyticus (6% vs. 4%). In addition, the main fungal species identified (ORs vs. wards) were Cladosporium sp. (37% vs. 38%), Penicillium sp. (28% vs. 22%), and Aspergillus Niger (21% vs. 12%). A statistically significant correlation was observed between the mean concentration of bio-aerosols and population density (p<0.05). Conclusion: Furthermore, a statistically significant difference was observed between the mean concentrations of bio-aerosols and the values recommended by WHO (p<0.05), linked presumably to inadequate disinfection, improper design and operation of standard central ventilation (SCV), and the high density of visitors and patients. Addressing such issues can help reduce airborne fungi and bacteria in hospital.
Keywords :
Bioaerosol , Hospital , Indoor air quality , Bacteria , Fungi , Iran
Journal title :
Journal of Air Pollution and Health
Serial Year :
2021
Record number :
2714276
Link To Document :
بازگشت