Abstract :
This article presents the reflection coefficient measurement by using a wideband multi-port reflectometer for microwave imaging application of human head. The configuration of the proposed wideband multiport reflectometer is formed by passive components, which are four couplers and two power dividers operating from 1 to 6 GHz. The investigation is successfully done through simulation using the Agilent’s Advanced Design Systems (ADS) software and practical measurement in laboratory. An error correction method with three standards of match, open and short load is then applied to the constructed wideband multi-port reflectometer to remove its imperfect characteristics. The wideband characteristics of proposed reflectometer are analyzed and verified across the designated frequency band. Its operation in reflection coefficient is tested with the chosen device under test (DUT).
Keywords :
Passive component , coupler , power divider , multi , port reflectometer , reflection coefficient , wideband , error correction