Title of article :
Inter and Intra-rater Reliability of Lateral Cephalometric Analysis Using 2D Dolphin Imaging Software
Author/Authors :
Khosravani, Sarvin Undergraduate Student - School of Dentistry - Shahid Beheshti University of Medical Sciences - Tehran, Iran , Esmaeili, Saharnaz Undergraduate Student - School of Dentistry - Shahid Beheshti University of Medical Sciences - Tehran, Iran , Malek Mohammadi, Nazanin Undergraduate Student - School of Dentistry - Shahid Beheshti University of Medical Sciences - Tehran, Iran , Eslamian, Ladan Dept. of Orthodontics - School of Dentistry - Shahid Beheshti University of Medical Sciences - Tehran, Iran , Dalaie, Kazem Dept. of Orthodontics - School of Dentistry - Shahid Beheshti University of Medical Sciences - Tehran, Iran , Motamedian, Saeed Reza Dept. of Orthodontics - School of Dentistry & Dentofacial Deformities Research Center - Research Institute of Dental Sciences - Shahid Beheshti University of Medical Sciences - Tehran, Iran
Pages :
5
From page :
148
To page :
152
Abstract :
Cephalometric radiographs are widely used in diagnosis and treatment planning. In the past, these radiographs used to be analyzed manually, but nowadays due to the possibility of errors and time-consuming nature of manual tracing, digital methods are replacing the manual methods. The reliability of computer-assisted analysis is of great importance. The purpose of this study was to investigate the inter and intra-rater reliability of 2D Dolphin imaging software version 10.0.00.53. Methods To assess the intra-rater reliability of lateral cephalometric analysis, 25 lateral cephalograms traced by one operator using Dolphin imaging software were traced again by the same examiner 2 weeks later. To assess the inter-rater reliability, 25 lateral cephalograms were traced independently by two examiners. Overall, 80 measurements including 43 linear, 34 angular, and 3 ratio measurements were made. The interclass correlation coefficient (ICC) was calculated to assess the inter-rater and intra-rater reliability. ICCs above 0.75 were considered good. Results The ICC for intra-rater reliability was above 0.75 for all parameters except lower vertical height depth ratio (ICC=0.51), inter-labial gap (ICC=0.54), superior sulcus depth (ICC=0.67), articular angle (ICC=0.733), and ramus height (ICC=0.728). The ICC for inter-rater reliability was above 0.75 for all parameters except nose prominence (ICC=0.73). Conclusion Dolphin imaging software showed good intra-rater reliability for most parameters and good inter-rater reliability for almost all parameters.
Keywords :
Digital Technology , Reproducibility of Results , Orthodontics , Cephalometry
Journal title :
Journal of Dental School
Serial Year :
2020
Record number :
2717602
Link To Document :
بازگشت