Zhang, G Department of Ultrasound Imaging - Pu Ren Hospital Affiliated to Wuhan University of Science and Technology - Wuhan, Hubei, China , Jiang, Y Department of Cardiology - Cardiac Function room - Pu Ren Hospital Affiliated to Wuhan University of Science and Technology - Wuhan, Hubei, China , Zhou, S Department of Ultrasound Imaging - Pu Ren Hospital Affiliated to Wuhan University of Science and Technology - Wuhan, Hubei, China , He, L Department of Ultrasound Imaging - Pu Ren Hospital Affiliated to Wuhan University of Science and Technology - Wuhan, Hubei, China , Chen, M Department of Ultrasound Imaging - Pu Ren Hospital Affiliated to Wuhan University of Science and Technology - Wuhan, Hubei, China , Long, Z Department of Ultrasound Imaging - Pu Ren Hospital Affiliated to Wuhan University of Science and Technology - Wuhan, Hubei, China , Xing, H Department of Hepatobiliary and Pancreatic Surgery - Pu Ren Hospital Affiliated to Wuhan University of Science and Technology - Wuhan, Hubei, China
Abstract :
Background: To explore the application of contrast-enhanced ultrasound and color Doppler ultrasonography in the treatment of primary hepatocellular carcinoma (PHC)
after Transhepatic Artery Chemoembolization (TACE). Materials and Methods: 49
patients with primary hepatocellular carcinoma were treated with TACE for 3-5 times.
Before and after treatment, digital subtraction angiography, contrast-enhanced
ultrasound and color Doppler ultrasound were performed. The lesions before and
after contrast-enhanced ultrasonography and color Doppler ultrasonography were
compared. The residual or recurrence and swelling of lesions before and after contrast
-enhanced ultrasonography and color Doppler ultrasonography were analyzed.
Detection of the capsule of the lesion. Results: The detection accuracy of contrastenhanced
ultrasound (95.77%) was significantly higher than that of color Doppler
ultrasound (84.51%) (P<0.05). The detection rate of tumor envelope by contrastenhanced
ultrasound (22.54%) was significantly higher than that by color Doppler
ultrasound (9.86%) (P < 0.05). The accuracy of detecting residual or recurrent lesions
by contrast-enhanced ultrasound (91.67%) was significantly higher than that by color
Doppler ultrasound (58.33%) (P<0.05). Conclusion: The rate of bone metabolism of
perimenopausal women in Xuzhou is not optimistic. We need to pay close attention to
the risk of bone metabolism disorder of perimenopausal women with older age,
diabetes mellitus and osteoporosis, so as to provide useful help for improving the quality of life of perimenopausal women in Xuzhou.
Keywords :
Contras t - enhanced ultrasound , color doppler ultrasound , primary liver cancer , therapeutic evaluation , therapeutic guidance