Title of article :
Pre-concentration and Sensitive Determination of Propranolol and Metoprolol Using Dispersive Solid-Phase Microextraction and High-Performance Liquid Chromatography in Biological, Wastewater, and Pharmaceutical Samples
Author/Authors :
Farhadi ، Bagher Department of Chemistry - Islamic Azad University, Mashhad Branch , Ebrahimi ، Mahmoud Department of Chemistry - Islamic Azad University, Mashhad Branch , Morsali ، Ali Department of Chemistry - Islamic Azad University, Mashhad Branch
Abstract :
Determination of drugs at environmental and biological samples is a critical issue for controlling the effects of a drug on human health and environmental pollution. In the present study, a dispersive solid phase microextraction mode was developed for the preconcentration and cleanup of low amounts of propranolol and metoprolol before their determination with a highperformance liquid chromatography diode array detector. Carboxyl functionalized singlewalled carbon nanotubes supported by magnetic nanoparticles (Fe3O4@SWCNTCOOH) were synthesized as a sorbent using a chemical procedure. Various factors affecting the microextraction method such as pH, donor phase volume, extraction desorption time, sorbent quantity solvent type and volume, and stirring rate were evaluated along with improving efficiency. The dynamic linear range of the method for the propranolol and metoprolol determination was 0.1234 and 0.2187 mg L-1 with a determination correlation coefficient (R2) of 0.9989 and 0.9984, respectively. Besides, the enrichment factor for the determination of propranolol and metoprolol were 283.1 and 278.7, respectively. Limit of detection (LOD) and limit of quantification (LOQ) were turn down by 0.06 and 0.2 for the analyte determination, correspondingly. Intraday and interday RSD% were determined for five times to determine propranolol and metoprolol at a concentration of 2.0 ng.m-1 and were lower than 3.26 and 4.29%, respectively. Determination of propranolol and metoprolol in hospital wastewater, human urine and plasma samples indicated that this proposed method can be employed to analyze the actual samples without the significant matrix effects with a recovery range of 91.097.2% and an RSD of less than 5.49%.
Keywords :
Propranolol , Metoprolol , Single , walled carbon nanotubes , Dispersive solid , phase microextraction , Magnetic nanoparticles , Hospital wastewater samples
Journal title :
Chemical Methodologies
Journal title :
Chemical Methodologies