Title of article :
Quantitative Bioanalytical and Analytical Methods for Estimation of Ivabradine Hydrochloride in Pure and Pharmaceutical Dosage Form
Author/Authors :
Polker, Anjali Department of Pharmaceutical Analysis - G. Pulla Reddy College of Pharmacy - Osmania University, Telangana, India , Padmavathi, Yenumula Department of Pharmaceutical Analysis - G. Pulla Reddy College of Pharmacy - Osmania University, Telangana, India , Kumar, Ravi Department of Pharmaceutical Analysis - G. Pulla Reddy College of Pharmacy - Osmania University, Telangana, India , Raghavendra Babu, Nayaka Department of Pharmaceutical Analysis - G. Pulla Reddy College of Pharmacy - Osmania University, Telangana, India
Abstract :
Introduction: New analytical and bioanalytical methods were developed for the estimation of Ivabradine
hydrochloride in bulk and pharmaceutical dosage form by UV spectrophotometry and high-performance
liquid chromatography (HPLC) technique. Objective: The primary objective of the study is to develop a
new RP-HPLC method for estimation of Ivabradine Hydrochloride in pure and formulation and to develop
a bioanalytical method for analysis of Ivabradine Hydrochloride in biological samples. The methods were
validated as per International Council for Harmonisation of Technical Requirements for Pharmaceuticals
for Human Use and USFDA guidelines respectively. Methods: In Reversed-phase (RP)-HPLC method
developed telmisartan is the internal standard used. After liquid–liquid extraction, the analyte and the
internal standard were chromatographed on Waters 125A (10 μ, 300 × 3.9 mm) C18 column using 20-
μL injection volume with a run time of 15 min. An isocratic mobile phase consisting of acetonitrile and
ammonium acetate buffer pH 7.8 (60:40% vol/vol) is used to separate drug and internal standard. In
Spectrophotometric bioanalytical method developed for the estimation of ivabradine hydrochloride in
pure and pharmaceutical dosage form. The solvent system used is absolute methanol and detected at the
wavelength of 287 nm. The solvent system used is absolute methanol and detected at the wavelength
of 287 nm. Results: The Analytical method is validated according to ICH guidelines over the range of
2–16 μg/ mL, showing accuracy, precision, selectivity, and robustness. For Bioanalytical method the
linearity is established in the range of 500–3500 ng/mL with the regression coefficient of r2 = 0.9994.
The validated spectrophotometric method is used successfully to study ivabradine hydrochloride in rat
plasma and also quantitative determination in marketed tablets. Conclusion: The proposed methods were
successfully applied for the quantitation of ivabradine hydrochloride in pharmaceutical dosage form with
good recovery and reproducibility.
Keywords :
Bioanalytical method , ivabradine hydrochloride , reversed-phase high-performance liquid chromatography , UV-spectrophotometric method
Journal title :
Journal of Reports in Pharmaceutical Sciences