Title of article :
Measurement of Deby length By using single probe technique
Author/Authors :
salman, emad a. thi-qar university - college of science - department of physics, Iraq , ghazai, alaa j. thi-qar university - college of science - department of physics, Iraq
From page :
46
To page :
49
Abstract :
In this work the planer magnetron sputtering device was used. As well as a 1mm copper diameter and 3 mm length Langmuir probe was used a diagnostic device to investigate electron temperature, electron density and Deby length under different pressure at distance 0.7 cm from the anode surface was measured.The effect of the pressure on plasma parameter was studied at this distance.The result of this work shown that, when the pressure increased the electron temperature and Deby length will decreased while the electron density increased.
Journal title :
Journal of Thi-Qar Science
Journal title :
Journal of Thi-Qar Science
Record number :
2724694
Link To Document :
بازگشت