Title of article :
A Proposed Methodology for Magnetic Resonance Images’ Geometrical Distortion Correction Intended To Use For Radiotherapy Planning Using a Large Inhouse Field of View
Author/Authors :
Atefeh ، Rostami Department of Medical Physics and Radiological Sciences - Sabzevar University of Medical Sciences , Naseri ، Shahrokh Medical Physics Research Center - Mashhad University of Medical Sciences , Momennezhad ، Mahdi Nuclear Medicine Research Center - Mashhad University of Medical Sciences , Zare ، Hoda Medical Physics Research Center - Mashhad University of Medical Sciences , Anvari ، Kazem Department of Radiotherapy Oncology and Cancer Research Center - Mashhad University of Medical Sciences , Sayah ، Hamed Reza Kowsar MRI Center - Emam Reza Hospital , Vejdani Noghreiyan ، Vajiheh Medical Physics and Radiological Sciences Department - Sabzevar University of Medical Sciences
From page :
305
To page :
314
Abstract :
Introduction: Exquisite soft tissue contrast of magnetic resonance images (MRI) and the new combined radiotherapy system of MR-Linac have been the main impetus for applying MR imaging in radiotherapy. One limitation of MR-based radiotherapy is the geometric distortion of MR images that can generate errors in the contouring and dosimetry stages. This study aimed to evaluate and correct geometric distortion for radiotherapy applications. Material and Methods: A large field of view (FOV) phantom develop using Perspex sheets and 325 plastic pipes. The quantification and correction of MR images system-related geometric distortion are conducted for HASTE protocol by MATLAB and 3D slicer software in phantom and patient images. The effect of MRI images geometrical distortion was evaluated for ten patients undergoing body radiotherapy treatment. CT images were used as a primary dataset to estimate the distortion map. Results: The phantom investigation results indicate that in radial distances of 13 cm (or FOVs 25 cm), the amount of distortion is under 2 mm. Still, at more considerable radial distances, distortion may increase up to about 3.5 cm. MR images of Patients with lateral (LAT) and anterior-posterior (AP) diameters of more than 38 cm and 25 cm respectively, need to be corrected for geometric distortion. Conclusion: MR images geometric precision in large FOVs is not sufficient for MRI only treatment planning of radiotherapy and further corrections are required. The B-spline deformable registration method can correct the MR geometric distortion until an acceptable range of 2 mm for radiotherapy applications.
Keywords :
Geometrical Distortion , Spatial Distortion , Correction , 3D Slicer , Scatter Transform , B , Spline Deformable , Registration
Journal title :
Iranian Journal of Medical Physics (IJMP)
Journal title :
Iranian Journal of Medical Physics (IJMP)
Record number :
2727012
Link To Document :
بازگشت