Title of article
Performance of a portable mini solar-pond
Author/Authors
Probert، S.D. نويسنده , , Tahat، M.A. نويسنده , , Kodah، Z.H. نويسنده , , AI-Tahaineh، H. نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2000
Pages
-298
From page
299
To page
0
Abstract
For the present experiments, such a pond was located at JUST, i.e. at 32?N latitude. Its walls were inclined at 45? to the horizontal. The pond was built of galvanized steel (1.44 mm thick) with a circular surface area and total depth of I m^2 and 500 mm, respectively. The effects of the solar-pondʹs depth and its waterʹs salinity on the storeʹs temperature distributions were determined experimentally and compared with theoretical predictions. A dimensional analysis was carried out to show the effect of the mini solar-pondʹs size on its thermal behaviour.
Keywords
Non-domestic buildings , Energy efficiency , Building design
Journal title
Applied Energy
Serial Year
2000
Journal title
Applied Energy
Record number
3611