Title of article :
Minimization of wiring inductance in high power IGBT inverter
Author/Authors :
Lounis، نويسنده , , Z.، نويسنده , , Rasoanarivo، نويسنده , , I.، نويسنده , , Davat، نويسنده , , B.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Abstract :
The wiring inductance is one of main causes limiting
the use of the inverter, in hard commutation mode, particularly
when voltage, current and switching frequency are increased. The
bus bar technology is the mean that allows to reach low wiring inductance
between DC source and power switches in spite of relatively
long connections. This paper deals with studies of bus bar
structure applied to the high power inverters in order to improve
their performances.
Two structures of wiring are tested; the traditional one and bus
bar technology. The experimental and simulation results show that
this last technique permits to obtain very low wiring inductance so
that no snubber circuits are needed.
Keywords :
IGBT , stray inductance , busbar , over voltage inverter.
Journal title :
IEEE TRANSACTIONS ON POWER DELIVERY
Journal title :
IEEE TRANSACTIONS ON POWER DELIVERY