Title of article :
Attenuation characteristics of high rate home-networking PLC signals
Author/Authors :
Kim، نويسنده , , C.J.، نويسنده , , A. Raouf Chouikha، نويسنده , , M.F.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Abstract :
This paper reports an experimental investigation of
the influence of the high-frequency (HF) signal attenuation on the
load in residences and offices. A laboratory test and actual measurements
were performed in a residence and an office. The experiments
show that the attenuation characteristics are more dependent
on the number of loads than the type of loads connected.
In addition, the concentration of loads was found to determine
where the maximum attenuation of the HF signals would occur.
The types and the size of the loads, however, did not affect the attenuation
characteristics of the HF signals. Therefore, for a successful
high-rate power line carrier (PLC) home networking, the analysis
on the placement of the loads may have to be considered for better
understanding of signal attenuation for PLC modems and other
PLC-to-media adapters.
Keywords :
home networking , power line carrier , PLC modem , signal attenuation.
Journal title :
IEEE TRANSACTIONS ON POWER DELIVERY
Journal title :
IEEE TRANSACTIONS ON POWER DELIVERY