Title of article :
Stockbridge-type damper effectiveness evaluation. I. Comparison between tests on span and on the shaker
Author/Authors :
Diana، نويسنده , , G.، نويسنده , , A. Cigada، نويسنده , , A.، نويسنده , , Belloli، نويسنده , , M.، نويسنده , , S. Malavasi and M. Vanali، نويسنده , , M.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Abstract :
This paper deals with an experimental measurement
campaign carried out with a modified dynamometric Stockbridge
damper clamped to a laboratory test span. The aim is to get the
force and the torque exerted between the cable and the damper
on a span. This approach allows “ONE”? to obtain the mechanical
impedance of the damper under real working conditions, with
the possibility to separate the contribution of the torque and of the
force out of the global losses, and to compare these results with
those obtained on a shaker where only the vertical motion is imposed,
with no rocking.
More than 100 experimental test were executed from February
2001 to July 2001, also looking for a metrological validation of the
results and for quality assessment of the collected data.
In the following, some results are shown, pointing out a comparison
between the damper behavior on the span and on dynamic
exciter.
Keywords :
cable damping , Cable vibration , stockbridge damper. , Aeolian vibration
Journal title :
IEEE TRANSACTIONS ON POWER DELIVERY
Journal title :
IEEE TRANSACTIONS ON POWER DELIVERY