Title of article :
Stockbridge-type damper effectiveness evaluation. II. The influence of the impedance matrix terms on the energy dissipated
Author/Authors :
Diana، نويسنده , , G.، نويسنده , , Manenti، نويسنده , , A.، نويسنده , , Pirotta، نويسنده , , C.، نويسنده , , Zuin، نويسنده , , A.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
8
From page :
1470
To page :
1477
Abstract :
This paper deals with a methodology to evaluate the 2 2 mechanical impedance matrix of a nonsymmetric Stockbridge-type damper, based on damper translational tests on a shaker and on a 6 d.o.f model of the damper itself. A series of comparisons with data measured on a laboratory span is reported, in order to investigate the effect of the single matrix terms on the global energy dissipation. The results of a software simulating the aeolian vibration behavior of a cable+damper system, accounting for the most important terms of the damper impedance matrix, are also presented.
Keywords :
damper 2 2 compleximpedance matrix , Aeolian vibration , Stockbridge-type damper.
Journal title :
IEEE TRANSACTIONS ON POWER DELIVERY
Serial Year :
2003
Journal title :
IEEE TRANSACTIONS ON POWER DELIVERY
Record number :
400528
Link To Document :
بازگشت