Title of article :
Study of Parameters of a Tripler Using the Finite Element Method of Harmonic Balance
Author/Authors :
J. H. Wang، نويسنده , , X. F. Wang ، نويسنده , , Y. H. Song، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Abstract :
In this paper, a new harmonic balance analysis approach
based on the finite element method (HBFEM) is used to
calculate the equivalent leakage reactance and the core loss in a
magnetic frequency tripler. The HBFEM presented can be used to
analyze harmonic magnetic field for time periodic magnetic field
with B H curve described by any high order polynomial. Consequently,
the current and flux density waveforms include many
harmonic terms caused by saturation. An equivalent leakage reactance
model of magnetic frequency tripler is presented based
on the harmonic terms. The resulted harmonic-rich flux density
waveforms are used to calculate core losses and equivalent leakage
reactance. Simulation results are compared with experiment results
and it is shown that the approach and model are correct and
practical.
Keywords :
Finite element method , Core losses , Harmonic balance , leakage inductance model.
Journal title :
IEEE TRANSACTIONS ON POWER DELIVERY
Journal title :
IEEE TRANSACTIONS ON POWER DELIVERY