Title of article :
Determining the number of interpole turns needed for the perfect commutation of a DC machine
Author/Authors :
Parsley، نويسنده , , G.M.J.; Landy، نويسنده , , C.F.; Meyer، نويسنده , , A.S.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1996
Abstract :
The authors describe a method of
determining the number of interpole windings
needed for the perfect commutation of a DC
machine. The primitive slip-ring model of the
machine is used to extract an equation that can
ultimately be used to derive an expression
describing the current in the conductors
undergoing commutation at the end of the
commutation period. The coefficients of this
expression that depend on some form of
inductance are readily obtained by the application
of finite-element analysis. One of the coefficients
obtained in this way depends on the interpole
strength of the machine. To ensure perfect
commutation, it is shown that this particular
coefficient must arise from the correct number of
interpole turns employed in the finite-element
analysis model.
Keywords :
DC machine , Commutation , Interpole turns
Journal title :
IEE Proceedings Electric Power Applications
Journal title :
IEE Proceedings Electric Power Applications