Title of article :
New snubber circuit with passive energy recovery for power inverters
Author/Authors :
He، نويسنده , , X.; Williams، نويسنده , , B.W.; Finney، نويسنده , , S.J.; Qian، نويسنده , , Z.; Green، نويسنده , , T.C.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1996
Abstract :
The paper proposes a new passive
circuit for partial snubber-energy recovery in
GTO thyristor high-power voltage-source
inverters. The analysis and simulations sh,ow that
the proposed bridge-leg snubber circuit can
recover greater than sixty five per cenl of the
total snubber energy, as well as the freewheel
diode reverse recovery energy. This energy is
recovered back to the DC supply through a
closely coupled transformer, without any active
devices or associated control circuitry. This
snubber circuit, being simple, is particularly
suitable for use in GTO thyristor high-power
inverters. Design equations, simulations and
experimental results are given.
Keywords :
Irverter , GTO thyristor , Snubber , Energy recovery
Journal title :
IEE Proceedings Electric Power Applications
Journal title :
IEE Proceedings Electric Power Applications