Effects of using DC-side average current-mode control on a three-phase converter with an input filter and distorted supply
Author/Authors :
Tooth، نويسنده , , D.J.; Finney، نويسنده , , S.J.; Williams، نويسنده , , B.W.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Abstract :
The use of DC-side current sensing and proportional plus integral average current-mode
control is aiialysed and shown to have several bencficial effects when applied to a three-phase, stepdown,
AC-DC, unity-power-factor converter. Conventionally, a large DC-side inductor was uscd with
the considered converter, in order to reduce the propagation of harmonic currcnts due to nonsinusoidal
supply voltages that result in the input currents being non-sinusoidal. A single DC-sidc
currcnt sensor, when used with an EPROM sinusoidal look-up tablc PWM modulation method, is
shown to have a number of benefits including; reduction or thc harmonic currents when a finite-value
DC-side inductor is used, hence giving near-sinusoidal input currcnts and damping of tlie DC-side LC
filler. Two other benefits arc mentioned. The current-control loop is dcsigncd and the often ignored
effect of the input filter on system stability is discussed. Two SIMULIN Kʹ" simulation models arc
developed and compared with each other.