Title of article :
Parameter estimation of squirrel-cage induction motors without torque measurements
Author/Authors :
Pedra، نويسنده , , J.; Sainz، نويسنده , , L.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
A very simple method for determining squirrel-cage induction motor parameters is
presented, and some problems in the determination of parameters with two methods proposed in
IEEE Standard 112 are discussed and clarified. The double-cage model is used to describe the
motor response for the entire operating range. Equivalent circuit parameters are calculated from
data of three tests: no-load test, locked-rotor test and overload test. The method has the advantage
of not requiring torque measurements. It is formulated as an iterative algorithm, and has been
tested with 16 motors of different power ratings, showing very good convergence. The influence of
measurement errors on the stability of the proposed method has been studied and its behaviour is
very good
Journal title :
IEE Proceedings Electric Power Applications
Journal title :
IEE Proceedings Electric Power Applications