Title of article
Performance of BDFM as generator and motor
Author/Authors
McMahon، نويسنده , , R.A.; Roberts، نويسنده , , P.C.; Wang، نويسنده , , X.; Tavner، نويسنده , , P.J.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2006
Pages
11
From page
289
To page
299
Abstract
The performance of the brushless doubly-fed machine (BDFM) is analysed using a perphase
equivalent circuit. An expression for the rating of the machine as a function of magnetic and
electric loadings is developed, and the rating is compared to those of the doubly-fed induction
machine and cascaded induction machines. As the magnetic field in a BDFM is complex, the
magnetic loading is considered in detail and a new generalised loading is derived. The BDFM
suffers a reduction rating of about one-quarter in comparison to comparable conventional
machines, arising from penalties in magnetic and electric loadings consequent on the presence of
two stator to rotor couplings. The handling of reactive power has an important effect on the
machine performance and this point is illustrated with experimental results from a frame size 180
BDFM. The tests were carried out at modest flux densities to avoid the effects of saturation, but
the implications of saturation are considered.