Acoustic transfer function of cavity and its application to rapid evaluation of sound field at low frequency band
Author/Authors
Gang، YIN نويسنده , , Hualing، CHEN نويسنده , , Xuanli، HU نويسنده , , Xieqing، HUANG نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
-72
From page
73
To page
0
Abstract
A new method to obtain numerical solution of Acoustic Transfer Function (ATF) by BEM is presented. For a simply supported panel backed by a rectangular cavity at low frequency band (0-200 Hz), the frequency property of ATF is analyzed. The relation between the accuracy of the rapid evaluation of sound field and the discretization schemes of the vibrational panel is discussed. The result shows that the method to obtain ATF and the rapid evaluation of sound field using the ATF is suitable to low frequency band. If an appropriate discretization scheme is choosed based on the frequency involved and the effort to obtain ATF, the accuracy of the rapid evaluation of sound field is acceptable.