Title of article :
Neutronic analysis of a moderated (D, T) fusion driven hybrid blanket
Author/Authors :
Hüseyin Yapici، نويسنده , , S.Orhan Akansu، نويسنده , , Veysel Ozceyhan، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Pages :
8
From page :
1237
To page :
1244
Abstract :
In this study, neutronic effects on (D-T) driven hybrid reactor fuelled with different mixtures of 45.5% fertile fuels, vary from 0 to 100% for uranium components and from 100 to 0% for the thorium component in the fuel mixtures. These mixtures are UF4+THF4, UO2+ThO2, UC2+ThC2. The coolants are selected as flibe (Li2BeF4), natural lithium and air for the heat transfer out of the fuels zones and the clad material is selected as SS-316 stainless steel with a volume fraction ratio of 9%. The fuel zones of the hybrid reactor are investigated to obtain fissile fuel breeding (233U and/or 239Pu). A regeneration period of up to 48 months is investigated by a plant factor of 75% under a first wall neutron flux (φw) of 2.22·1014 (14.1 MeV) n/cm2.s for a conventional (D,T) driven hybrid reactor. These correspond to a first wall neutron load of 5 MW/m2. At the end of the operation periods, cumulative fissile fuel enrichment (CFFE) value varies between 6.7% in pure UF4 with flibe coolant and 3.5% in pure ThO2 with natural lithium coolant. At the beginning of the operation, the tritium breeding ratio (TBR) is higher than unity in air coolant and natural lithium coolant cases. In flibe coolant cases the TBR value can reach nearly 55% uranium component +45% thorium components. Therefore, the hybrid blanket is self-sufficient with respect to the TBR for these cases. It is important to follow the non-prolific level of the plutonium fuel during operation because of the nuclear weapons hazard. Nuclear quality of the plutonium increases linearly during the operation period. 240Pu content has to be higher than 5% for safety. 240Pu content is higher than 5% in UF4 + ThF4, UC2 + ThC2 and (UO2>20%) + (ThO2<80%) with flibe coolant. This is very important criteria for safety. In natural lithium and air coolant cases 240Pu content is lower than 5%. In these cases, the operation period must be increased for safety. 233U is used as a fuel in thermal reactors and can be separated from the Thourium component. But this separation is too difficult in the thorium component + uranium component mixtures. Therefore, investigated hybrid blanket is safer than 100% Th component.
Journal title :
Annals of Nuclear Energy
Serial Year :
2000
Journal title :
Annals of Nuclear Energy
Record number :
405466
Link To Document :
بازگشت