Title of article :
Assessment of core protection and monitoring systems for an advanced reactor SMART
Author/Authors :
Wang Kee In، نويسنده , , Dae Hyun Hwang، نويسنده , , Yeon Jong Yoo، نويسنده , , Sung Qunn Zee، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Pages :
13
From page :
609
To page :
621
Abstract :
Analogue and digital core protection/monitoring systems were assessed for the implementation in an advanced reactor. The core thermal margins to nuclear fuel design limits (departure from nucleate boiling and fuel centerline melting) were estimated using the design data for a commercial pressurized water reactor and an advanced reactor. The digital protection system resulted in a greater power margin to the fuel centerline melting by at least 30% of rated power for both commercial and advanced reactors. The DNB margin with the digital system is also higher than that for the analogue system by 8 and 12.1% of rated power for commercial and advanced reactors, respectively. The margin gain with the digital system is largely due to the on-line calculations of DNB ratio and peak local power density from the live sensor signals. The digital core protection and monitoring systems are, therefore, believed to be more appropriate for the advanced reactor.
Journal title :
Annals of Nuclear Energy
Serial Year :
2002
Journal title :
Annals of Nuclear Energy
Record number :
405643
Link To Document :
بازگشت