Title of article :
Utilization of ilmenite/epoxy composite for neutrons and gamma rays attenuation
Author/Authors :
A. El-Sayed Abdo، نويسنده , , M. A. El-Sarraf، نويسنده , , F. A. Gaber، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Abstract :
This work deals with the study of ilmenite/epoxy composite as an injecting mortar for cracks developed in biological concrete shields, as well as, neutrons and gamma rays attenuation. Effects of the particle size on the mechanical strengths have been studied for epoxy resin filled with crushed ilmenite with different maximum particle sizes ranging from 32 to 500 μm. Thermal neutrons and gamma rays attenuation in ilmenite/epoxy composites with 75 and 80 wt.% of ilmenite concentration have been investigated. The total mass attenuation coefficients μ/ρ (cm2 g−1) of gamma ray for five ilmenite/epoxy composites have been calculated using the XCOM program (version 3.1) at energies from 10 keV to 100 MeV. Also, the total mass attenuation coefficients (μ/ρ) have estimated based on the measured total linear attenuation coefficients (μ) and compared with the calculated results where, a reasonable agreement was found.
Journal title :
Annals of Nuclear Energy
Journal title :