Title of article :
Analysis of the cooling capability of steam generators during the loss of residual heat removal system at midloop operation with closed primary system
Author/Authors :
Cesar Queral، نويسنده , , Isaac Gonzalez، نويسنده , , Antonio Exposito، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
Loss of residual heat removal system (RHRS) at midloop operation is one of the most significant core damage risk contributor at low
power and shutdown conditions. During this kind of transients the reflux-condensation is one of the cooling mechanisms anticipated in
the abnormal procedure of loss of RHRS at midloop level. In this sense, several simulations of loss of the RHRS with closed primary
system with the TRACE V4.160 code have been performed considering different availability of steam generators. The present study aims
to analyze the thermal-hydraulic behavior after the loss of RHRS at midloop conditions with the reflux-condensation as the only cooling
mechanism available and to investigate the capability of this cooling mechanism. The simulation results show that one steam generator is
sufficient to remove core decay heat of 11 MWobtaining an equilibrium pressure, but the core uncovery depends on the number of steam
generators operating. Finally, an analysis of the abnormal procedure and the event trees of the loss of RHRS sequences at midloop operation
has been performed taking into account the results obtained in the simulation with TRACE.
Journal title :
Annals of Nuclear Energy
Journal title :
Annals of Nuclear Energy