• Title of article

    Thermal comfort in passive solar earth integrated rooms

  • Author/Authors

    Peter Sobotka، نويسنده , , Hiroshi Yoshino، نويسنده , , Shin-Ichi Matsumoto، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1996
  • Pages
    12
  • From page
    155
  • To page
    166
  • Abstract
    Presented are the two-year temperature and relative humidity measurements in semi-underground rooms in Sendai, Japan, and one year measurements in fully earth integrated rooms in Brhlovce, Slovakia. The monthly mean and daily mean spring and summer data are shown together with Predicted Mean Vote (PMV) indices. Similar data on air temperatures were found as in the previous studies. However, the more complex evaluation of thermal comfort using PMV index helped to determine that fully earth integrated rooms without insulation and proper design of transparent constructions may be cold in spring and even summer in a temperate climate. This finding is different from previous studies, which stated that earth integrated spaces in temperate climates were comfortable on the basis of air temperatures alone. The degree of earth integration, the level of insulation of the earth in contact with construction, and the size of south oriented transparent construction were found to be the key parameters of passive solar earth shelter design and conclusions were drawn regarding their implementation in various climates for optimal control of spring and summer thermal environment.
  • Journal title
    Building and Environment
  • Serial Year
    1996
  • Journal title
    Building and Environment
  • Record number

    408055