• Title of article

    Hygrothermal system-performance of a whole building

  • Author/Authors

    Achilles Karagiozis، نويسنده , , Mikael Salonvaara، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2001
  • Pages
    9
  • From page
    779
  • To page
    787
  • Abstract
    In this paper the full house hygrothermal performance of an aerated concrete wall system is examined for the hot and humid climate of Miami. The results clearly demonstrated the limited drying potential for the wall system in that climate. The selected exterior thermal insulation strategies and interior vapor control strategies in this study show the critical behavior of the full house with respect to drying initial construction moisture. Moisture related problems such as mold growth are simulated and discussed. From these results moisture control strategies are identified for the whole house hygrothermal performance.
  • Keywords
    Building envelope modeling , Whole building performance , Aerated concrete , Moisture control , Moisture engineering
  • Journal title
    Building and Environment
  • Serial Year
    2001
  • Journal title
    Building and Environment
  • Record number