Probabilistic assessment of the potential impacts of vent-free gas products on indoor relative humidity
Author/Authors
Gary K. Whitmyre، نويسنده , , Muhilan D. Pandian، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
7
From page
1179
To page
1185
Abstract
A probabilistic analysis with the American Gas Association Research Division model and Crystal BallTM determined the contribution of vent-free gas appliances to total indoor relative humidity (RH). At least 20,000 simulations were conducted for each DOE Heating Region. Vent-free heating contributed to average indoor RH as little as 4% for DOE Region I, to up to 43% for Region V across all scenarios. The great majority of cases in all DOE regions were associated with RH levels from all indoor water vapor sources that were less than the 70% RH concern level for active mold and mildew growth.
Keywords
Indoor humidity , Stochastic modeling , Mold and mildew , Gas appliance