• Title of article

    An analysis of measured and simulated daylight illuminance and lighting savings in a daylit corridor

  • Author/Authors

    Danny H.W. Li، نويسنده , , Ernest K.W. Tsang، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    10
  • From page
    973
  • To page
    982
  • Abstract
    Lighting control integrated with daylighting is recognised as an important and useful strategy in energy-efficient building designs and operations. Prediction of the internal daylight levels is a key stage in daylighting designs. With the advances in computer technology, the computation of daylight illuminances can be conducted via lighting simulation program. This paper presents a study of the daylight coefficient (DC) approach using RADIANCE lighting software in simulating the indoor daylight illuminance of a corridor. The interior daylight illuminance data measured in the corridor were compared with the simulated results based on the computer software. It was found that the DC approach could give satisfactory results especially for the sun-shaded surface and sun-facing surface receiving a large amount of direct sunlight. Further, the daylight illuminance detected by the photosensor was also simulated in conjunction with measured daylight illuminance, dimming ratio and electric lighting power to predict the lighting energy savings. The findings suggested that the measured and predicted data showed a good agreement when large electric lighting savings resulted. The probable reasons causing the discrepancies were discussed.
  • Keywords
    Sky luminance , Daylight coefficient , Dimming controls , Daylight illuminance , Electric lighting
  • Journal title
    Building and Environment
  • Serial Year
    2005
  • Journal title
    Building and Environment
  • Record number

    408967