  • Abstract
    This study focuses on comparing the performance of submerged membrane bioreactor (SMBR) and submerged membrane adsorption bioreactor (SMABR) over a period of 20 days at a hydraulic retention time (HRT) of 3.1 h. The effects of PAC on critical flux and membrane fouling were also investigated. The SMABR exhibited better results in terms of mixed liquor suspended solids (MLSS) growth, DOC removal (over 96%), COD removal (over 95%), transmembrane pressure (TMP) and oxygen uptake rate. Nearly 100% of bacteria and 100% of total coliforms were removed in both systems. The addition of PAC could maintain the critical flux at a lower TMP value (7.5 kPa), while irreversible fouling caused by PAC occurred when the filtration flux exceeded critical flux.
  • Keywords
    adsorption , Submerged membrane bioreactor , oxygen uptake rate , Critical flux