• Title of article

    Heat-exchanger performance: Influence of gap width between consecutive vertical rectangular fin-arrays

  • Author/Authors

    C. W. Leung، نويسنده , , S. D. Probert، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1997
  • Pages
    8
  • From page
    1
  • To page
    8
  • Abstract
    Two identical rectangular heat-exchanger fin-arrays, with their bases in the same vertical plane, arranged in series one above the other, were used instead of a single array of double the original length fins to dissipate heat from a vertical rectangular base, which was kept at 40°C above the ambient environment. The effect of the magnitude of the gap width between the two consecutive arrays, upon the steady-state rate of heat transfer from the heated base of the exchanger under natural-convection conditions, was investigated experimentally. When a gap width of 18 ± 2 mm is used, a saving in fin material ensues together with a slight ( 3%) increase in the rate of heat dissipation, being achieved.
  • Journal title
    Applied Energy
  • Serial Year
    1997
  • Journal title
    Applied Energy
  • Record number

    414201