Title of article :
Optimization of excess air for the improvement of environmental performance of a 150 MW boiler fired with Thai lignite
Author/Authors :
V. I. Kouprianov، نويسنده , , V. Tanetsakunvatana، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
9
From page :
445
To page :
453
Abstract :
The results of an experimental study of the excess-air-dependent heat losses, as well as gaseous emissions (NOx, SO2 and CO), on a 150 MW boiler firing Thai lignite are discussed. The NOx emissions were found to increase with the higher excess air ratios; the NOx values in the flue gas (at 6% O2) ranged from 257 to 325 ppm, whilst the excess air ratio varied from 1.06 to 1.32 at the economizer outlet. Owing to the highly-efficient operation of the flue gas desulfurization units, the SO2 emissions from the unit were maintained at a relatively low level, 50–76 ppm for the above excess-air ratios, whereas they accounted for about 3100–3300 ppm at the inlet of the FGD units. The CO emissions were determined for the extremely low excess air ratios. Two approaches for the optimization of the excess air ratio were analyzed in this study. For the first, i.e. the conventional approach, the optimization was carried out based on minimizing the total excess-air-dependent heat losses. The second, the environmentally friendly approach, proposed in this work, was aimed at minimizing the “external” costs (or the costs of damage done by the boiler emissions to the environment and humans). As shown in this paper, the lignite firing at the optimal excess air results in a lower environmental impact by the boiler unit.
Keywords :
Excess-air optimization , Gaseous emissions , heat losses , boiler efficiency
Journal title :
Applied Energy
Serial Year :
2003
Journal title :
Applied Energy
Record number :
414449
Link To Document :
بازگشت