Title of article
Standardization of Methods for Fluence (UV Dose) Determination in Bench-Scale UV Experiments
Author/Authors
Linden، Karl G. نويسنده , , Bolton، James R. نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2003
Pages
-208
From page
209
To page
0
Abstract
Ultraviolet (UV) disinfection is now an accepted technology for inactivation of a variety of waterborne pathogens in wastewater and drinking water. However, the techniques used in much of the previous research aimed at providing information on UV effectiveness have not yet been standardized. Thus in many peer reviewed published literature, it is not clear how the UV irradiations were carried out, nor how the average fluence (or UV dose) given to the microorganisms has been determined. A detailed protocol for the determination of the fluence (UV dose) in a bench scale UV apparatus containing UV lamps emitting either monochromatic or broadband UV light was developed. This protocol includes specifications for the construction of a bench scale UV testing apparatus, methods for determination of the average irradiance in the water, details on UV radiometry, and considerations for microbiological testing. Use of this protocol will aid in standardization of bench scale UV testing and provide increased confidence in data generated during such testing.
Keywords
Function algebra , C^*-algebra , Toeplitz representation
Journal title
JOURNAL OF ENVIRONMENTAL ENGINEERING
Serial Year
2003
Journal title
JOURNAL OF ENVIRONMENTAL ENGINEERING
Record number
41521