Title of article
Exergy analysis of a liquid-desiccant-based, hybrid air-conditioning system
Author/Authors
C.S Khalid Ahmed، نويسنده , , P Gandhidasan، نويسنده , , S.M Zubair، نويسنده , , A.A Al-Farayedhi، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1998
Pages
9
From page
51
To page
59
Abstract
We present the applicable exergy analysis and estimate irreversible losses that are generated during operation of a hybrid air-conditioning cycle with emphasis on a partly closed solar regenerator that is used to regenerate weak desiccant. The desiccant mass-flow rate has been chosen as the fundamental parameter for analysing the system. We find an optimum mass-flow rate for minimum irreversibility, i.e. maximum exergy. Large irreversibilities occur for high ambient vapor pressures, which tend to decrease the system exergy and overall performance of the regenerator.