• Title of article

    Performance evaluation of small size externally fired gas turbine (EFGT) power plants integrated with direct biomass dryers

  • Author/Authors

    Daniele Cocco، نويسنده , , Paolo Deiana، نويسنده , , Giorgio Cau، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    13
  • From page
    1459
  • To page
    1471
  • Abstract
    This paper concerns a performance evaluation of a small scale (about 100 kWe), externally fired gas turbine (EFGT) fuelled by residual biomass and integrated with a biomass dryer. In biomass fuelled EFGT power plants, compressed air is heated in the high temperature heat exchanger by using the hot gases produced by the biomass combustion process. The hot air expands in the turbine and then feeds the biomass furnace. The exhaust waste heat is recovered by drying the raw biomass in a rotary dryer and, in case, in a low temperature heat exchanger for hot water production.
  • Journal title
    Energy
  • Serial Year
    2006
  • Journal title
    Energy
  • Record number

    416830