Title of article :
Influence of ambient temperatures on performance of a CO2 heat pump water heating system
Author/Authors :
Ryohei Yokoyama، نويسنده , , Takeshi Shimizu، نويسنده , , Koichi Ito، نويسنده , , Kazuhisa Takemura، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
11
From page :
388
To page :
398
Abstract :
In residential applications, an air-to-water CO2 heat pump is used in combination with a domestic hot water storage tank, and the performance of this system is affected significantly not only by instantaneous ambient air and city water temperatures but also by hourly changes of domestic hot water consumption and temperature distribution in the storage tank. In this paper, the performance of a CO2 heat pump water heating system is analyzed by numerical simulation. A simulation model is created based on thermodynamic equations, and the values of model parameters are estimated based on measured data for existing devices. The calculated performance is compared with the measured one, and the simulation model is validated. The system performance is clarified in consideration of seasonal changes of ambient air and city water temperatures.
Keywords :
Thermodynamics , System performance , CO2 , Cycle analysis , Thermal storage , Numerical simulation , Refrigerant , Heat pump