Abstract :
This paper presents results of a theoretical study carried out to investigate the effect of flow maldistribution, caused by the
manufacturing imperfections and tolerances, on the thermal efficiency of a solar air heater array with subcollectors in parallel. The air
mass flow rate, ambient temperature, solar insolation and wind heat transfer coefficient have been systematically varied to study the
effect under a wide range of these parameters. The collector length, duct height, and plate emissivity were also changed to study their
effect. It has been found that the maximum reduction in thermal efficiency due to flow maldistribution is less than about 3% for an array
with a commercial grade finish of duct surfaces and 710% manufacturing tolerance for the duct height.