Title of article :
Batch phenol removal from methyl isobutyl ketone by liquid–liquid extraction with chemical reaction
Author/Authors :
M.S.A. Palma، نويسنده , , J.L. Paiva، نويسنده , , M. Zilli، نويسنده , , A. Converti، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Abstract :
The aim of this work was to investigate in a bench-scale mixed vessel the influence of temperature, NaOH concentration in the extracting aqueous phase and rotational speed on the batch removal of phenol from a 14.4% solution in methyl isobutyl ketone. To this purpose, temperature was varied in the range 10–40 °C, the concentration of NaOH between 5.5 and 6.5% and the rotational speed from 400 to 800 rpm. The average residual concentration of phenol in the organic phase was as less as 0.40–1.0%, corresponding to removal efficiencies of 94.0–97.6%, respectively.
Keywords :
phenol , Chemical reaction , Liquid–liquid extraction , Methyl isobutyl ketone
Journal title :
Chemical Engineering and Processing: Process Intensification
Journal title :