Title of article :
Determination of the interfacial area of a continuous integrated mixer/separator (CINC) using a chemical reaction method
Author/Authors :
B. Schuur، نويسنده , , W.J. Jansma، نويسنده , , J.G.M. Winkelman، نويسنده , , H.J. Heeres، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
8
From page :
1484
To page :
1491
Abstract :
The effect of the liquid flow rates (18–100 mL/min) and rotor frequency (30–60 Hz) on the interfacial area of a liquid–liquid system in a CINC-V02 continuous integrated mixer/separator have been studied using a chemical reaction method. Typical specific interfacial areas were in the range of 3.2 × 102 to 1.3 × 104 m2 m−3 liquid volume, which is comparable with those for a continuously stirred tank reactor (CSTR). A pronounced maximum in the interfacial area with respect to the rotor frequency was found at about 45 Hz. The interfacial area increased considerably at higher aqueous phase flow rates whereas the organic phase flow rate had no significant effect. The experimental data were modelled using an empirical model. Good agreement between experiments and model was observed.
Keywords :
Process intensification , CINC , Interfacial area , Chemical reaction method
Journal title :
Chemical Engineering and Processing: Process Intensification
Serial Year :
2008
Journal title :
Chemical Engineering and Processing: Process Intensification
Record number :
418704
Link To Document :
بازگشت