Title of article :
Performance evaluation of an integrated solar water heater as an option for building energy conservation
Author/Authors :
C. Dharuman، نويسنده , , J.H. Arakeri، نويسنده , , K. Srinivasan، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
6
From page :
214
To page :
219
Abstract :
Since a majority of residential and industrial building hot water needs are around 50 °C, an integrated solar water heater could provide a bulk source that blends collection and storage into one unit. This paper describes the design, construction and performance test results of one such water-heating device. The test unit has an absorber area of 1.3 m2 and can hold 170 l of water, of which extractable volume per day is 100 l. Its performance was evaluated under various typical operating conditions. Every morning at about 7:00 a.m., 100 l of hot water were drawn from the sump and replaced with cold water from the mains. Although, during most of the days, the peak temperatures of water obtained are between 50 and 60 °C, the next morning temperatures were lower at 45–50 °C. Daytime collection efficiencies of about 60% and overall efficiencies of about 40% were obtained. Tests were conducted with and without stratification. Night radiation losses were reduced by use of a screen insulation.
Keywords :
convection , Screen insulation , Integrated solar water heater , Solar energy , Energy storage