Title of article
Development and preliminary evaluation of double roof prototypes incorporating RBS (radiant barrier system)
Author/Authors
Pei-Chi Chang، نويسنده , , Che-Ming Chiang، نويسنده , , Chi-Ming Lai، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2008
Pages
8
From page
140
To page
147
Abstract
Double-skin roof is known as a very effective way to reduce both the conduction and convection heat transfers from roof to the ceiling of building, on the other hand, RBS (radiant barrier system) is very effective in blocking the radiation heat transfer between roof and ceiling. In this study, prototypical double roofs inspired by the concepts of both double-skin structure and RBS technique was specifically designed to cut down the solar heat gain from roof. The effect of energy saving was experimentally measured. A double roof structure, formed by a roof plate and an aluminum foil-PP (polypropylene) board-RC slab, can achieve good performance of heat barrier and is highly recommended.
Keywords
RBS (radiant barrier system) , Heat gain , Double roof , Double skin
Journal title
Energy and Buildings
Serial Year
2008
Journal title
Energy and Buildings
Record number
419996
Link To Document