Title of article
Heat transfer and pressure drop measurements in rib-roughened rectangular ducts
Author/Authors
Xiufang Gao، نويسنده , , Bengt Sundén، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
10
From page
25
To page
34
Abstract
In the present study, the thermal and hydraulic performance of three rib-roughened rectangular ducts is investigated. The aspect ratio of the ducts was 1 to 8, and the ribs were arranged staggered on the two wide walls. Three rib configurations were tested: parallel ribs and V-shaped ribs pointing upstream or downstream of the main flow direction. For all cases, the rib height-to-hydraulic diameter ratio was 0.06, with an attack angle of 60° and a pitch-to-height ratio of 10. The Reynolds number range was from 1000 to 6000. Liquid crystal thermography was employed in the heat transfer experiment to demonstrate detailed temperature distribution between a pair of ribs on the ribbed surfaces. The secondary flows caused by the inclined ribs create a significant spanwise variation of the heat transfer coefficients on the rib-roughened wall with high heat transfer coefficient at one end of the rib and low value at the other. In the streamwise direction between two consecutive ribs, the temperature distribution shows a sawtooth fashion because of flow reattachment. Based on the local heat transfer coefficients, the average Nusselt numbers were estimated as weighted mean values. Isothermal pressure drop data were taken and presented as Fanning friction factors. The ducts are compared to each other by considering both heat transfer and friction factor performance.
Keywords
Rib-roughened duct , heat transfer enhancement , Liquid crystal thermography , pressure drop
Journal title
Experimental Thermal and Fluid Science
Serial Year
2001
Journal title
Experimental Thermal and Fluid Science
Record number
420361
Link To Document