Title of article
Measurements of the Thermal Conductivity of HFC-125 in the Temperature Range from 300 to 515 K at Pressures up to 53 Mpa
Author/Authors
B. Le Neindre and Y. Garrabos ، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1999
Pages
25
From page
375
To page
399
Abstract
Measurements of the thermal conductivity of HFC-125 that have been made by
a coaxial cylinder cell operating in steady state are reported. The measurements
of the thermal conductivity of HFC-125 were performed along several quasiisotherms
between 300 and 515 K in the gas phase and the liquid phase. The
pressure range covered varies from 0.1 to 53 MPa. Based on the measurement
of more than 600 points, an empirical equation is provided to describe the thermal
conductivity outside the critical region as a function of temperature and
density. A careful analysis of the various sources of error leads to an estimated
uncertainty of approximately ± 1.5%.
Keywords
thermalconductivity. , coaxial cylinders , Refrigerants , HFC-125 , High pressure
Journal title
International Journal of Thermophysics
Serial Year
1999
Journal title