Abstract :
A subsecond pulse heating method was applied to measure the specific heat capacity, electrical resistivity, total hemispherical emissivity, and normal spectral emissivity of 99.9% pure tantalum in the form of 2-mm-diameter wire. W/Re thermocouple thermometry was applied from 300 to 2300 K, with emissivity measurements above 1300 K involving pyrometric measurements. The maximum uncertainties in the specific heat capacity and electrical resistivity were less than 3 and 1 % respectively. The uncertainty of emissivity measurements was estimated as +5%. The results are compared with literature values.
Keywords :
Electrical conductors , Electrical resistivity , normal spectral emissivity , High temperatures , refractory metals , tantalum. , specific heat , hemispherical totalemissivity