Title of article :
Density Measurement of Molten Silicon by a Pycnometric Method
Author/Authors :
Y. Sato، نويسنده , , T. Nishizuka، نويسنده , , K. Hara، نويسنده , , T. Yamamura and Y. Waseda ، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2000
Abstract :
The density of molten silicon was measured using a newly developed pycnom-
eter made of boron nitride. The present method has many advantages for
measuring the density of molten silicon, which has a high temperature and can
be easily oxidized. The pycnometer was precisely machined, and its volume at
high temperatures was acculately determined. The procedure to overflow the
excess melt was carried out in a closed apparatus under a helium atmosphere.
A special procedure was introduced to avoid the error generated by the volume
expansion of silicon when it solidified. The total uncertainty of the measurement
was estimated to be within 0.50. The measured density showed a linear rela-
tionship with respect to temperature and agreed well with literature values. The
expansion coefficient of molten silicon was similar to those of typical molten
metals in spite of the low expansion coefficient of solid silicon. This suggested
that the structural change of molten silicon was similar to those of typical metals.
Keywords :
pycnometer , Semiconductor , silicon. , molten state , Density
Journal title :
International Journal of Thermophysics
Journal title :
International Journal of Thermophysics