Title of article :
An Improved Transient Calorimetric Technique for Measuring the Total Hemispherical Emittance of Nonconducting Materials (Emittance Evaluation of Glass Sheets)
Author/Authors :
H. Masuda، نويسنده , , S. Sasaki، نويسنده , , H. Kou and H. Kiyohashi ، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Abstract :
For measurements of the total hemispherical emittance eh of nonconducting
materials, a problem of the thermal gradient produced in a sample specimen
arises. An improved transient calorimetric technique to reduce the thermal gradient
is proposed in this study. Glass sheets (borosilicate), semi-transparent for
radiation, are selected as the nonconducting test material. The eh values of the
glass sheets for various thicknesses are measured, and their results are preseInted
as functions of thickness and temperature. The thermal gradients in the specimens
are calculated by a three-dimensional analysis, and the corner effect due to
them on the measured eh is estimated. It is shown that the proposed technique is
useful for measuring the emittance eh of nonconducting materials.
Keywords :
glass sheet , nonconducting materials , total hemispherical emittance , thermal radiation. , calorimetric technique
Journal title :
International Journal of Thermophysics
Journal title :