Abstract :
The thermal diffusivity and effective infrared emissivity of water–methanol mixtureswere
measured at atmospheric pressure and ambient temperature using a pyroelectric
thermal-wave resonator cavity. The applied frequency-scan method allows
keeping the cavity length fixed, which eliminates instrumental errors and substantially
improves the precision and accuracy of the measurements.Atheoretical model
describing conduction and radiation heat transfer in the cavity was developed. The
model predictions and the frequency-scan experimental datawere compared, showing
excellent agreement. The measurements were performed for methanol volume
fractions of 0, 0.5, 1, 2, 5, 10, 20, 40, 75, and 100%. The fitted thermal diffusivity
and effective emissivity vs. concentration results of the mixtures were compared to
literature theoretical and experimental data. The maximum resolution of 0.5% by
volume of methanol in water by means of the thermal-wave cavity method is the
highest reported to date using thermophysical techniques. Semi-empirical expressions
for the mixture thermal diffusivity and infrared emissivity as functions of
methanol concentration have been introduced. The expression for infrared emissivity
is consistent with the physical principle of detailed balance (Kirchhoff’s law).
The expression for thermal diffusivity was found to describe the data satisfactorily
over the entire methanol volume-fraction range.
Keywords :
photopyroelectric technique , thermal-wave resonator cavity , Mixtures , thermal diffusivity , water , Methanol , infrared emissivity