Title of article :
Indoor Radon Radioactivity at the University of Brunei Darussalam
Author/Authors :
T.K. Sheng، نويسنده , , H.S. Jer ، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2003
Abstract :
Indoor radon radioactivity in the rooms on the ground floor and first floor of the Physics
Department, Faculty of Science, Universiti Brunei Darussalam was measured using a system that consists
of an air filter pump, ZnS detector, photomultiplier tube and counter. Ground floor rooms’ radon
radioactivity was found to be about three times higher than that of the first floor. The maximum ground
floor indoor radioactivity is only 0.39 Bqm)3, a value relatively low and safe compared to the mean
outdoor radon concentration of 1.41 Bqm)3 measured (HU and TAN, 2000). The main source of radon
emanation originates from the ground soil rather than the building materials.