Title of article :
Indoor Radon Radioactivity at the University of Brunei Darussalam
Author/Authors :
T.K. Sheng، نويسنده , , H.S. Jer ، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2003
Pages :
6
From page :
75
To page :
80
Abstract :
Indoor radon radioactivity in the rooms on the ground floor and first floor of the Physics Department, Faculty of Science, Universiti Brunei Darussalam was measured using a system that consists of an air filter pump, ZnS detector, photomultiplier tube and counter. Ground floor rooms’ radon radioactivity was found to be about three times higher than that of the first floor. The maximum ground floor indoor radioactivity is only 0.39 Bqm)3, a value relatively low and safe compared to the mean outdoor radon concentration of 1.41 Bqm)3 measured (HU and TAN, 2000). The main source of radon emanation originates from the ground soil rather than the building materials.
Keywords :
radon , indoor radioactivity. , RADIOACTIVITY
Journal title :
Pure and Applied Geophysics
Serial Year :
2003
Journal title :
Pure and Applied Geophysics
Record number :
429537
Link To Document :
بازگشت