Title of article :
Application of Normalized Full Gradient Method to Self Potential (SP) Data
Author/Authors :
Petek S?nd?rg?، نويسنده , , Oya Pamukcu، نويسنده , , ?enol ozyal?n ، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2008
Abstract :
Recently, Normalized Full Gradient (NFG) method has widespread applications to natural
potential fields, especially in gravity and magnetic. In this study, usage of NFG in Self-Potential (SP) data
evaluation is tested. Results are compared to other SP interpretation methods. The NFG method is applied to
synthetic and field SP data. As a consequence of application of the method to the anomalies of spherical,
cylindrical and vertical sheet models, whose theoretical structures are explicit, the structures were found very
close to their actual locations. In order to see the capability of the method in detecting the number of sources,
NFG method was applied to different spherical models at different depths and locations. The least-squares
inverse solution was applied to the same models and NFG method was found more powerful in detecting
model structure. Sensitivity of NFG method for application to noisy data is also tested. An anomaly is
generated by adding a random noise to two close sphere SP anomalies. The method seems to work for the two
close spheres at high S/N ratio. Then, NFG method was applied to two field examples. The first one is the
cross section taken from the SP anomaly map of the Ergani-Su¨leymanko¨y (Turkey) copper mine. The depth of
the mineral deposit at that site was found about 38 m from the ground level. This result is well matched to
previous studies. NFG was also applied to SP data from Seferihisar Izmir (Western Turkey) geothermal field
and the location of the point source was determined. The field data of this site have already been modeled by
the thermoelectric source (coupling) solution method. When these two methods are compared, they seem to
support each other. It is concluded that the NFG method works perfectly when the structure model is simple.
It is observed that natural potential sources close to earth’s surface are identified by the method more
accurately at greater harmonics, while deep sources are identified at lesser harmonics. It produces reasonable
results for noisy multi-source models than the other parameter identification methods (inverse solution, power
spectrum, etc.).
Keywords :
downward continuation , thermo-electric source , depth estimates , selfpotentialsource geometry. , Singular points
Journal title :
Pure and Applied Geophysics
Journal title :
Pure and Applied Geophysics