Comment on ?Measurement of Aerosol Absorption Coefficient from Teflon Filters using the Integrating Plate and Integrating Sphere Techniques by D. Campbell, S. Copeland and T. Cahill
Author/Authors :
Clarke، نويسنده , , A.; Ogren، نويسنده , , J.; Charlson، نويسنده , , R، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1996
Pages :
4
From page :
221
To page :
224
Abstract :
Campbell et al. (1995) present a study of the light transmitted by and reflected from Teflon filters, and claim that the Laser Integrating Plate Method (LIPM), a variant of the Integrating Plate Method (IPM; Lin et aI., 1973), provides accurate determination of the light absorption coefficient of the particles deposited on the filters. Close examination of the paper reveals that it is an incomplete evaluation of a technique that is inappropriately compared to a questionable facsimile of an established method (IPM) , and that the authors have not demonstrated that the LIPM technique provides accurate measurements of aerosol absorption coefficient. As a result of the lack of corrections for multiple scattering and absorption in the Teflon filters, data obtained with the LIPM (e.g., MaIm et aI., 1994) may significantly overestimate the true aerosol absorption coefficient.