Title of article :
Penetration of Nanometer-Sized Aerosol Particles Through Wire Screen and Laminar Flow Tube
Author/Authors :
Alonso، نويسنده , , M.; Kousaka، نويسنده , , Y.; Hashimoto، نويسنده , , T.; Hashimoto، نويسنده , , N، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1997
Abstract :
Penetration of nanometer-sized aerosol particles and ions through a
single wire screen and a laminar flow tube has been measured using a tandem
differential mobility analyzer system to accurately determine the size of the particles.
The results obtained using a condensation nucleus counter as a particle
detector showed that penetration of particles down to 2 nm in particle diameter
f,ollows the predictions of the theories of Cheng and Yeh and Gormley and
Kennedy. This result suggests that thermal rebound of particles on wire or tube
surfaces does not occur. The measured penetrations for negative ions smaller than 2
nm also agreed well with the theoretical predictions. In this case, however, concentration
was measured with an electrometer, and there exists the possibility of
electron transfer between the ions and the surfaces without the (neutralized) ions
being attached to them.
Journal title :
Aerosol Science and Technology
Journal title :
Aerosol Science and Technology